The A10VO45 is an axial piston variable displacement pump designed for open-circuit hydraulic systems — meaning oil is drawn from a reservoir, pressurized, sent to the actuator, and returned to the tank, rather than circulating in a closed loop between pump and motor (as you'd see in a hydrostatic transmission).
Why Engineers Choose the A10VO45 Series 32
Energy Efficiency Through Demand-Matched Flow
A fixed-displacement pump running at, say, 1,800 rpm always delivers the same flow, whether the actuator needs it or not. The excess has to go somewhere — usually back to tank through a relief valve, converting hydraulic energy straight into heat. The A10VO45's variable displacement means the pump only produces the flow the circuit is actually calling for, cutting parasitic power loss and reducing oil cooling requirements.
Compact Power Density
For its footprint and weight, the A10VO45 delivers a lot of usable hydraulic power. That matters on mobile equipment where every kilogram and every centimeter of engine bay space is contested real estate.
Broad Control Flexibility
Series 32 pumps are available with a wide range of control options, so the same base pump can be configured for very different jobs:
DR (pressure control): Holds a set maximum pressure, reducing flow as the system approaches that limit.
DFR (pressure and flow control): Combines pressure limiting with flow/power control for load-sensing style circuits.
DG (two-point control): Switches between two discrete displacement settings.
EO / EP (electro-hydraulic or electro-proportional control): Lets a controller vary displacement electronically — useful when the pump needs to respond to a PLC or vehicle ECU.
LR / LRDW (load-sensing variants): Matches pump output directly to the flow demanded by a downstream directional valve, minimizing throttling losses.
Durability in Demanding Duty Cycles
The axial piston design tolerates high-pressure, high-cycle operation better than most vane or gear pumps, which is why it shows up so often on equipment that works hard for years: telehandlers, cranes, presses, and construction machinery.
Installation and Maintenance Considerations
Hydraulic Fluid and Cleanliness
Like any precision piston pump, the A10VO45 Series 32 is unforgiving of dirty oil. Rexroth specifies a cleanliness level of at least ISO 4406 20/18/15 under normal conditions, tightening to 19/17/14 at high fluid temperatures. Most premature pump failures trace back to contamination, not the pump design itself — so filtration specification and maintenance discipline matter as much as the pump selection.
Viscosity Range
The pump is typically rated for hydraulic fluids in the ISO VG 32–68 range depending on ambient and operating temperature, with defined limits for cold-start viscosity and continuous operating viscosity. Running fluid outside the optimum range accelerates wear and can starve the pump on the suction side.
Suction Conditions
Because it's a variable piston pump, the A10VO45 is more sensitive to suction starvation than a gear pump. Inlet line sizing, reservoir height relative to the pump, and minimum absolute pressure at the suction port all need to be checked against the data sheet — especially on mobile applications where the pump may be mounted above the tank.
Shaft Seal and Alignment
Misalignment between the pump shaft and the prime mover (engine or electric motor) is one of the most common causes of premature shaft seal failure. Flexible couplings, correct spacer dimensions, and respecting maximum radial/axial shaft loads all extend service life.
Common Failure Modes and What They Signal
Loss of flow at operating temperature but not cold — often points to worn piston/cylinder bore clearances allowing internal leakage as viscosity drops with heat.
Excessive noise or cavitation sound — usually a suction-side issue: clogged filter, undersized inlet line, or air ingress at a fitting.
Erratic pressure control — can indicate a sticking control piston, contaminated control orifice, or a failing pressure compensator spring.
External leakage at the shaft — typically a worn shaft seal, frequently accelerated by misalignment or case pressure exceeding the seal's rating.
For more information on the A10VO45 hydraulic pump, please visit https://www.baolilaihydraulic.com/.
Specifications
| Size | NG | 45 | 71 | 100 | 140 | 180 | ||
| Displacement, geometric, per revolution | Vg max | cm3 | 45 | 71 | 100 | 140 | 180 | |
| Rotational speed maximum | at Vg max | nnom | rpm | 3000 | 2550 | 2300 | 2200 | 1800 |
| Flow | at nnom and Vg max | qv | l/min | 135 | 181 | 230 | 308 | 324 |
| at nE=1500 rpm | qvE | l/min | 67.5 | 106.7 | 150 | 210 | 270 | |
| Power at Δp=280 bar | at nnom, Vg max and Δp=280 bar | P | kW | 62.8 | 85 | 107 | 144 | 151 |
| at nE=1500 rpm | PE | kW | 31 | 50 | 70 | 98 | 98 | |
| Torque | at nnom, Vg max and Δp=280 bar | T | Nm | 200 | 317 | 446 | 624 | 802 |
| at nnom, Vg max and Δp=100 bar | T | Nm | 72 | 113 | 159 | 223 | 286 | |
| Rotary stiffness of drive shaft | P | c | Nm/rad | 34587 | 80627 | 132335 | 188406 | 213022 |
| S | c | Nm/rad | 29497 | 71884 | 121142 | 169537 | 171107 | |
| R | c | Nm/rad | 41025 | 76545 | - | - | - | |
| Moment of inertia for rotary group | JTW | kgm2 | 0.0035 | 0.0087 | 0.0185 | 0.0276 | 0.033 | |
| Maximum angular acceleration | α | rad/s2 | 2000 | 2900 | 2400 | 2400 | 2000 | |
| Case volume | V | l | 1.0 | 1.6 | 2.2 | 3.0 | 2.7 | |
| Weight (approx.) | m | kg | 30 | 47 | 69 | 73 | 78 | |
Selection Table


| A10VO45 Hydrauilc Pump | |
| Model No. | Model Code |
| R902490315 | AA10VO45DRS/32R-VUD12N00-SO413 |
| R902514650 | AA10VO45LA6D/32R-VRC22U68H-S3814 |
| R902555003 | AA10VO45LA6D/32R-VSC12K68 |
| R902572643 | AA10VO45LA6DS/32R-VSC72U01-SO413 |
| R902515891 | AA10VO45LA7D/32R-VRC22U68H-S3814 |
| R902553519 | AA10VO45LA7DG/32R-VSC72U00E |
| R902516335 | AA10VO45LA8D/32R-VRC22U68H-S3814 |
| R902570434 | AA10VO45LA8D/32R-VSC12K68 |
| R902490314 | ALA10VO45DRS/32R-VUD12N00-SO413 |
| R902550330 | ALA10VO45LA5D/32R-VRC22U68H-S3814 |
| R902514648 | ALA10VO45LA6D/32R-VRC22U68H-S3814 |
| R902569986 | ALA10VO45LA7D/32R-VRC22U52-S5580 |
| R902565468 | ALA10VO45LA7D/32R-VRC22U68H-S3814 |
| R902551919 | ALA10VO45LA7D/32R-VRC22U68H-S3814 |
| R902534975 | ALA10VO45LA7D/32R-VRC22U68H-S3814 |
| R902534974 | ALA10VO45LA7D/32R-VRC22U68H-S3814 |
| R902515890 | ALA10VO45LA7D/32R-VRC22U68H-S3814 |
| R902570786 | ALA10VO45LA8D/32R-VRC22U00H-S3814 |
| R902574489 | ALA10VO45LA8D/32R-VRC22U68H-S3814 |
| R902573009 | ALA10VO45LA8D/32R-VRC22U68H-S3814 |
| R902566722 | ALA10VO45LA8D/32R-VRC22U68H-S3814 |
| R902516334 | ALA10VO45LA8D/32R-VRC22U68H-S3814 |
| R902542027 | ALA10VO45LA9D/32R-VRC22U68H-S3814 |
Q1: What does "Series 32" actually mean on a Rexroth A10VO pump?
A1: It denotes a specific generation of the A10VO design — covering mounting dimensions, control hardware, and minor engineering updates. Series numbers (like 10, 31, 32, 52) are not interchangeable; a Series 32 pump won't necessarily bolt up or interchange controls with a Series 52 unit of the same displacement.
Q2: How often should the hydraulic fluid be checked or changed?
A2: There's no single universal interval — it depends on duty cycle, ambient temperature, and filtration quality. Rather than a calendar-based rule, most reliability programs monitor fluid cleanliness (via particle counts against ISO 4406) and viscosity/degradation, changing fluid when those metrics drift out of spec.
Q3: How to purchase an A10VO45 hydraulic pump?
A3: You can visit https://www.baolilaihydraulic.com/contact/ to contact us and purchase our products through various methods.
Q4: What is the price and delivery time of the A10VO45 hydraulic pump?
A4: The specific price and delivery time will be provided based on the specific model you provide.