Home / Product /

Rexroth Hägglunds CCE400 Marine low-speed radial piston hydraulic motor

pic1
pic1
  • pic1
  • pic2
  • pic3
  • pic4
  • pic5
SERIES : CCE
BRAND : For Bosch Rexroth Hägglunds
Model Size :CCE400
Displacement : 15100-35300cm3/rev
Speed : 53-125rpm
Maximum Pressure : 420bar
Nominal Pressure : 350bar
PDF封面
Download PDF

For more new products, please call us or email us

    *

    *

    1. Product Details
    2. Product Model
    3. FAQ

    The Hägglunds CCE400 is a direct-drive, low-speed, high-torque radial piston hydraulic motor. "Direct drive" is the key phrase here — instead of running a hydraulic motor through a gearbox to get usable torque at low shaft speeds, the CCE400 delivers full torque straight off its output shaft, from zero rpm, with no gear reduction stage in between.

    Where the CCE400 Gets Used

    The CCE400 shows up wherever you need serious torque at low, controllable speed, in a package that can take abuse. A few concrete examples:

    Anchor handling and mooring winches. A vessel paying out or hauling in mooring line under load needs a motor that can hold torque at a dead stop and respond instantly if the line load spikes. Direct-drive radial piston motors like the CCE400 eliminate the gearbox failure point that would otherwise be the weak link in that chain.

    Deck cranes and offshore crane slew drives. Slewing a crane under load demands smooth, precise torque control at low rpm — exactly the CCE400's operating window — plus the shock tolerance to handle a sudden gust or a load snagging.

    Trawl winches on fishing vessels. Continuous duty, variable load, and constant exposure to spray make this a textbook CB-series application; the sealed, direct-drive design keeps saltwater and grit away from gear teeth that would otherwise wear quickly.

    Shipboard cargo handling and hatch cover drives. Slow, high-torque, repetitive-cycle applications where reliability over tens of thousands of operating hours matters more than raw speed.

    Offshore construction and pipe-lay equipment. Tensioners, reel drives, and similar systems where torque needs to ramp instantly and hold steady under load.

    Installation and Operating Considerations

    A few things that matter in practice, not just on the datasheet:

    Oil viscosity and case temperature. Like other Hägglunds CCE motors, the CCE400 is rated for a working oil viscosity range and a case temperature ceiling — running outside that window (thick, cold oil at startup, or an overheated case in continuous high-load service) shortens bearing life well below the rated 40,000 hours. Cooling and filtration on the case drain circuit deserve real attention at the design stage, not as an afterthought.

    Charge pressure. Because the motor's torque calculation and rated life curves assume a specific charge pressure (commonly 15 bar in Rexroth's published data), undersizing the charge pump or restricting the drain line will both reduce actual torque output and accelerate wear.

    Mounting and external loads. The CCE400 can be shaft-mounted with a torque arm, flange-mounted, or fitted with pinion drive arrangements, but each mounting method has its own permissible radial and axial load limits. Marine installations in particular need to account for vibration and shock loading beyond the nominal duty cycle — this is one of the more common areas where field failures trace back to an installation detail rather than the motor itself.

    Corrosion protection selection. Standard C3 painting is fine for a sheltered machinery room; anything on an exposed deck or in a salt-laden atmosphere should be specified as C5M from the outset rather than retrofitted later.

    For more information on the CCE400 hydraulic motor, please visit https://www.baolilaihydraulic.com/product/.


    Specifications

    Item Unit CB 280 CB 400 CB 560 CB 840 CB 1120
    Pressure​ Maximum operating pressure bar 350 350 350 350 350
    psi 5076 5076 5076 5076 5076
    Maximum peak pressure bar 420 420 420 420 420
    psi 6091 6091 6091 6091 6091
    Charge pressure bar/psi See 4.4 Recommended charge pressure
    Maximum case pressure bar 3 3 3 3 3
    psi 44 44 44 44 44
    Maximum case peak pressure bar 8 8 8 8 8
    psi 116 116 116 116 116
    Temperature limits of case drain oil
    Seal type: NBR (Nitrile) Minimum -35 -35 -35 -35 -35
    -31 -31 -31 -31 -31
    Maximum 70 70 70 70 70
    158 158 158 158 158
    Seal type: FPM (Viton) Minimum -20 -20 -20 -20 -20
    100 100 100 100 100
    Maximum -4 -4 -4 -4 -4
    212 212 212 212 212
    Oil volume in motor case l 15 21 19 25 32
    US gal 4 5.6 5 6.6 8.5
    Moment of inertia for rotary group Motor with splined shaft kg·m² 7.2 15 18.1 31.1 42.1
    lbm·ft² 170859 355955 429520 738014 999048
    Motor with shrink coupling kg·m² 9.1 18.3 22.7 35.7 72.7
    lbm·ft² 215946 434266 538679 847174 1725197
    Weight Motor with splined shaft kg 705 1060 1115 1445 1770
    lb 1555 2335 2450 3185 3900
    Motor with shrink coupling kg 800 1160 1290 1620 2340
    lb 1760 2555 2840 3570 10692

     

    Frame size Nominal size Specific torque Displacement Maximum torque Maximum speed Maximum operating pressure Maximum operating power
    Nm/bar lbf·ft/1000 psi cm³/rev in³/rev kNm lbf·ft rpm p bar p psi kW hp
    CB 280 240 240 12200 15100 920 79 57000 68 350 5000 530 710
    280 280 14200 17600 1070 92 67000 58 350 5000 530 710
    CB 400 240 240 12200 15100 920 79 57000 125 350 5000 970 1300
    280 280 14200 17600 1070 92 67000 105 350 5000 950 1300
    320 320 16300 20100 1230 110 76000 94 350 5000 970 1300
    360 360 18300 22600 1380 120 86000 82 350 5000 960 1300
    400 400 20300 25100 1530 130 95000 75 350 5000 970 1300
    440 440 22400 27600 1690 131 97000 65 320 4600 820 1100
    480 480 24400 30200 1840 129 95000 62 290 4200 660 890
    520 520 26400 32700 1990 130 96000 57 270 3900 670 900
    560 560 28500 35200 2150 129 95000 53 250 3600 630 840
    CB 560 440 440 22400 27600 1690 140 100000 65 350 5000 930 1300
    480 480 24400 30200 1840 160 110000 62 350 5000 970 1300
    520 520 26400 32700 1990 170 140000 57 350 5000 960 1300
    560 560 28500 35200 2150 180 130000 53 350 5000 970 1300
    CB 840 600 600 30500 37700 2300 200 140000 45 350 5000 880 1200
    640 640 32500 40200 2450 210 150000 41 350 5000 850 1100
    680 680 34600 42700 2610 220 160000 40 350 5000 890 1200
    720 720 36600 45200 2760 240 170000 37 350 5000 870 1200
    760 760 38700 47800 2910 250 180000 34 350 5000 840 1100
    800 800 40700 50300 3070 260 190000 34 350 5000 890 1200
    840 840 42700 52800 3220 280 200000 32 350 5000 870 1200
    CB 1120 880 880 44700 55300 3370 290 210000 34 350 5000 970 1300
    920 920 46700 57800 3520 300 220000 33 350 5000 980 1300
    960 960 48800 60300 3680 315 230000 32 350 5000 990 1300
    1000 1000 50800 62800 3830 330 240000 31 350 5000 1000 1300
    1040 1040 52800 65300 3980 340 250000 29 350 5000 980 1300
    1080 1080 54900 67900 4140 355 260000 28 350 5000 980 1300
    1120 1120 56900 70400 4290 370 270000 27 350 5000 980 1300

    Selection Table

     

    CCE400 hydraulic motor
    Model No. Model Code Model Code
    R939069846 CCE 400 120 120 S 00 V 0 C C CCE400120120S00V0CC
    R939069847 CCE 400 120 120 S 00 V 0 C C CCE400120120S00V0CC
    R939069848 CCE 400 120 120 S 00 V 0 C C CCE400120120S00V0CC
    R939069849 CCE 400 120 120 S 00 V 0 C C CCE400120120S00V0CC
    R939069838 CCE 400 120 120 S 00 V 0 C F CCE400120120S00V0CF
    R939069839 CCE 400 120 120 S 00 V 0 C F CCE400120120S00V0CF
    R939069840 CCE 400 120 120 S 00 V 0 C F CCE400120120S00V0CF
    R939069841 CCE 400 120 120 S 00 V 0 C F CCE400120120S00V0CF
    R939069850 CCE 400 120 120 S 00 V H C C CCE400120120S00VHCC
    R939069851 CCE 400 120 120 S 00 V H C C CCE400120120S00VHCC
    R939069852 CCE 400 120 120 S 00 V H C C CCE400120120S00VHCC
    R939069853 CCE 400 120 120 S 00 V H C C CCE400120120S00VHCC
    R939069842 CCE 400 120 120 S 00 V H C F CCE400120120S00VHCF
    R939069843 CCE 400 120 120 S 00 V H C F CCE400120120S00VHCF
    R939069844 CCE 400 120 120 S 00 V H C F CCE400120120S00VHCF
    R939069845 CCE 400 120 120 S 00 V H C F CCE400120120S00VHCF
    R939069830 CCE 400 160 120 S 00 V 0 C C CCE400160120S00V0CC
    R939069831 CCE 400 160 120 S 00 V 0 C C CCE400160120S00V0CC
    R939069832 CCE 400 160 120 S 00 V 0 C C CCE400160120S00V0CC
    R939069833 CCE 400 160 120 S 00 V 0 C C CCE400160120S00V0CC
    R939069822 CCE 400 160 120 S 00 V 0 C F CCE400160120S00V0CF
    R939069823 CCE 400 160 120 S 00 V 0 C F CCE400160120S00V0CF
    R939069824 CCE 400 160 120 S 00 V 0 C F CCE400160120S00V0CF
    R939069825 CCE 400 160 120 S 00 V 0 C F CCE400160120S00V0CF
    R939069834 CCE 400 160 120 S 00 V H C C CCE400160120S00VHCC
    R939069835 CCE 400 160 120 S 00 V H C C CCE400160120S00VHCC
    R939069836 CCE 400 160 120 S 00 V H C C CCE400160120S00VHCC
    R939069837 CCE 400 160 120 S 00 V H C C CCE400160120S00VHCC
    R939069826 CCE 400 160 120 S 00 V H C F CCE400160120S00VHCF
    R939069827 CCE 400 160 120 S 00 V H C F CCE400160120S00VHCF
    R939069828 CCE 400 160 120 S 00 V H C F CCE400160120S00VHCF
    R939069829 CCE 400 160 120 S 00 V H C F CCE400160120S00VHCF
    R939069814 CCE 400 160 160 S 00 V 0 C C CCE400160160S00V0CC
    R939069815 CCE 400 160 160 S 00 V 0 C C CCE400160160S00V0CC
    R939069816 CCE 400 160 160 S 00 V 0 C C CCE400160160S00V0CC
    R939069817 CCE 400 160 160 S 00 V 0 C C CCE400160160S00V0CC
    R939069806 CCE 400 160 160 S 00 V 0 C F CCE400160160S00V0CF
    R939069807 CCE 400 160 160 S 00 V 0 C F CCE400160160S00V0CF
    R939069808 CCE 400 160 160 S 00 V 0 C F CCE400160160S00V0CF
    R939069809 CCE 400 160 160 S 00 V 0 C F CCE400160160S00V0CF
    R939069818 CCE 400 160 160 S 00 V H C C CCE400160160S00VHCC
    R939069819 CCE 400 160 160 S 00 V H C C CCE400160160S00VHCC
    R939069820 CCE 400 160 160 S 00 V H C C CCE400160160S00VHCC
    R939069821 CCE 400 160 160 S 00 V H C C CCE400160160S00VHCC
    R939069810 CCE 400 160 160 S 00 V H C F CCE400160160S00VHCF
    R939069811 CCE 400 160 160 S 00 V H C F CCE400160160S00VHCF
    R939069812 CCE 400 160 160 S 00 V H C F CCE400160160S00VHCF
    R939069813 CCE 400 160 160 S 00 V H C F CCE400160160S00VHCF
    R939069798 CCE 400 200 120 S 00 V 0 C C CCE400200120S00V0CC
    R939069799 CCE 400 200 120 S 00 V 0 C C CCE400200120S00V0CC
    R939069800 CCE 400 200 120 S 00 V 0 C C CCE400200120S00V0CC
    R939069801 CCE 400 200 120 S 00 V 0 C C CCE400200120S00V0CC
    R939069790 CCE 400 200 120 S 00 V 0 C F CCE400200120S00V0CF
    R939069791 CCE 400 200 120 S 00 V 0 C F CCE400200120S00V0CF
    R939069792 CCE 400 200 120 S 00 V 0 C F CCE400200120S00V0CF
    R939069793 CCE 400 200 120 S 00 V 0 C F CCE400200120S00V0CF
    R939069802 CCE 400 200 120 S 00 V H C C CCE400200120S00VHCC
    R939069803 CCE 400 200 120 S 00 V H C C CCE400200120S00VHCC
    R939069804 CCE 400 200 120 S 00 V H C C CCE400200120S00VHCC
    R939069805 CCE 400 200 120 S 00 V H C C CCE400200120S00VHCC
    R939069794 CCE 400 200 120 S 00 V H C F CCE400200120S00VHCF
    R939069795 CCE 400 200 120 S 00 V H C F CCE400200120S00VHCF
    R939069796 CCE 400 200 120 S 00 V H C F CCE400200120S00VHCF
    R939069797 CCE 400 200 120 S 00 V H C F CCE400200120S00VHCF
    R939069782 CCE 400 200 160 S 00 V 0 C C CCE400200160S00V0CC
    R939069783 CCE 400 200 160 S 00 V 0 C C CCE400200160S00V0CC
    R939069784 CCE 400 200 160 S 00 V 0 C C CCE400200160S00V0CC
    R939069785 CCE 400 200 160 S 00 V 0 C C CCE400200160S00V0CC
    R939069774 CCE 400 200 160 S 00 V 0 C F CCE400200160S00V0CF
    R939069775 CCE 400 200 160 S 00 V 0 C F CCE400200160S00V0CF
    R939069776 CCE 400 200 160 S 00 V 0 C F CCE400200160S00V0CF
    R939069777 CCE 400 200 160 S 00 V 0 C F CCE400200160S00V0CF
    R939069786 CCE 400 200 160 S 00 V H C C CCE400200160S00VHCC
    R939069787 CCE 400 200 160 S 00 V H C C CCE400200160S00VHCC
    R939069788 CCE 400 200 160 S 00 V H C C CCE400200160S00VHCC
    R939069789 CCE 400 200 160 S 00 V H C C CCE400200160S00VHCC
    R939069778 CCE 400 200 160 S 00 V H C F CCE400200160S00VHCF
    R939069779 CCE 400 200 160 S 00 V H C F CCE400200160S00VHCF
    R939069780 CCE 400 200 160 S 00 V H C F CCE400200160S00VHCF
    R939069781 CCE 400 200 160 S 00 V H C F CCE400200160S00VHCF
    R939069766 CCE 400 200 200 S 00 V 0 C C CCE400200200S00V0CC
    R939069767 CCE 400 200 200 S 00 V 0 C C CCE400200200S00V0CC
    R939069768 CCE 400 200 200 S 00 V 0 C C CCE400200200S00V0CC
    R939069769 CCE 400 200 200 S 00 V 0 C C CCE400200200S00V0CC
    R939069758 CCE 400 200 200 S 00 V 0 C F CCE400200200S00V0CF
    R939069759 CCE 400 200 200 S 00 V 0 C F CCE400200200S00V0CF
    R939069760 CCE 400 200 200 S 00 V 0 C F CCE400200200S00V0CF
    R939069761 CCE 400 200 200 S 00 V 0 C F CCE400200200S00V0CF
    R939069770 CCE 400 200 200 S 00 V H C C CCE400200200S00VHCC
    R939069771 CCE 400 200 200 S 00 V H C C CCE400200200S00VHCC
    R939069772 CCE 400 200 200 S 00 V H C C CCE400200200S00VHCC
    R939069773 CCE 400 200 200 S 00 V H C C CCE400200200S00VHCC
    R939069762 CCE 400 200 200 S 00 V H C F CCE400200200S00VHCF
    R939069763 CCE 400 200 200 S 00 V H C F CCE400200200S00VHCF
    R939069764 CCE 400 200 200 S 00 V H C F CCE400200200S00VHCF
    R939069765 CCE 400 200 200 S 00 V H C F CCE400200200S00VHCF
    R939069750 CCE 400 240 120 S 00 V 0 C C CCE400240120S00V0CC
    R939069751 CCE 400 240 120 S 00 V 0 C C CCE400240120S00V0CC
    R939069752 CCE 400 240 120 S 00 V 0 C C CCE400240120S00V0CC
    R939069753 CCE 400 240 120 S 00 V 0 C C CCE400240120S00V0CC
    R939069742 CCE 400 240 120 S 00 V 0 C F CCE400240120S00V0CF
    R939069743 CCE 400 240 120 S 00 V 0 C F CCE400240120S00V0CF
    R939069744 CCE 400 240 120 S 00 V 0 C F CCE400240120S00V0CF
    R939069745 CCE 400 240 120 S 00 V 0 C F CCE400240120S00V0CF
    R939069754 CCE 400 240 120 S 00 V H C C CCE400240120S00VHCC
    R939069755 CCE 400 240 120 S 00 V H C C CCE400240120S00VHCC
    R939069756 CCE 400 240 120 S 00 V H C C CCE400240120S00VHCC
    R939069757 CCE 400 240 120 S 00 V H C C CCE400240120S00VHCC
    R939069746 CCE 400 240 120 S 00 V H C F CCE400240120S00VHCF
    R939069747 CCE 400 240 120 S 00 V H C F CCE400240120S00VHCF
    R939069748 CCE 400 240 120 S 00 V H C F CCE400240120S00VHCF
    R939069749 CCE 400 240 120 S 00 V H C F CCE400240120S00VHCF
    R939069734 CCE 400 280 120 S 00 V 0 C C CCE400280120S00V0CC
    R939069735 CCE 400 280 120 S 00 V 0 C C CCE400280120S00V0CC
    R939069736 CCE 400 280 120 S 00 V 0 C C CCE400280120S00V0CC
    R939069737 CCE 400 280 120 S 00 V 0 C C CCE400280120S00V0CC
    R939069726 CCE 400 280 120 S 00 V 0 C F CCE400280120S00V0CF
    R939069727 CCE 400 280 120 S 00 V 0 C F CCE400280120S00V0CF
    R939069728 CCE 400 280 120 S 00 V 0 C F CCE400280120S00V0CF
    R939069729 CCE 400 280 120 S 00 V 0 C F CCE400280120S00V0CF
    R939069738 CCE 400 280 120 S 00 V H C C CCE400280120S00VHCC
    R939069739 CCE 400 280 120 S 00 V H C C CCE400280120S00VHCC
    R939069740 CCE 400 280 120 S 00 V H C C CCE400280120S00VHCC
    R939069741 CCE 400 280 120 S 00 V H C C CCE400280120S00VHCC
    R939069730 CCE 400 280 120 S 00 V H C F CCE400280120S00VHCF
    R939069731 CCE 400 280 120 S 00 V H C F CCE400280120S00VHCF
    R939069732 CCE 400 280 120 S 00 V H C F CCE400280120S00VHCF
    R939069733 CCE 400 280 120 S 00 V H C F CCE400280120S00VHCF

    Q1: Is the Hägglunds CB motor a piston motor or a gear motor?

    A1: It's a radial piston motor. Pistons arranged radially around the motor housing act against a cam profile, converting hydraulic pressure directly into torque without the reduction gearing that gear motors and many axial piston systems require.

    Q2: What industries commonly use the Hägglunds CB motor?

    A2: Mining and mineral processing, scrap and waste shredding, pulp and paper, rubber and tire manufacturing, marine deck machinery, and general heavy material handling are the most common application areas.

    Q3: What is the price and delivery time of the CCE400 hydraulic motor?

    A3: The price and delivery time will be provided based on the model you specify.

    Q4:How to purchase a CCE400 hydraulic motor?

    A4: You can visit https://www.baolilaihydraulic.com/contact/ to contact us and purchase our products via various methods.

    Welcome To Submit Your Inquiry
    Information To Us
    our engineer will contact with you as soon as possible.

      *

      *

      kefu
      Send Email
      QR
      QR
      TOP